Gastos estimados de envío
Payment & Security
Su información de pago se procesa de forma segura. No almacenamos los detalles de la tarjeta de crédito ni tenemos acceso a la información de su tarjeta de crédito.
Descripción
The MD Pro Microcap 9® handheld capnograph is a state-of-the-art medical device designed to accurately measure and monitor the level of carbon dioxide (CO2) in a patient's breath. This portable and lightweight device offers healthcare professionals a convenient and efficient tool for assessing respiratory function in various clinical settings.d clear images. With a patented fully digital step-up probe the MD5 requires no annual calibration.
Equipped with MoveOxy™ advanced digital Sp02, the MicroCap 9 handheld Capnograph and Oximeter is capable of severe monitoring conditions, providing reliable Sp02 and pulse rate measurements.
Features:
- 2.8 inch TFT, monitoring EtC02 /C02 , RR and Sp02 , PR
- Temperature, Pressure compensation system and Zero readjustment system
- Balance gas compensation minimizing infl uence against other gases
- Lung pressure and temperature compensation (BTPS compensation) avaiable
- Applicable for intubated or non-intubated patients
- Pump fl ux for adult and infant
- Water fi lter specially designed for heavy humid environment
- Audio and Visual alarm for exceeding limits and Apnea
- MoveOxy™ SpO2 module is capable of;
- 24 hours graphic trend can be stored after power-off
- Availability to purchase with optional Nellcor Sp02
- USB Connectivity to PC for data transfer
Package Includes:
- 2 x Reusable T3 water filter Part No:664511
- 1 x Sampling ine Part No:662503
- 1 x Airway adapter Part No:662531
- 1 x SpO2 Probe (Adult, clip, 0.9m) Part No:15040022
- 1 x Nasal CO2 Sampling Cannula - Adult
- USB Data Cable
- Silicon Cover
- Canvas Case
- Docking Base
- AC/DC Adapter
Warranty: Comes with 2 Years Manufacturer's Warranty
Specifications:
- Dimensions: 70 mm x 160 mm x 40 mm
-
Battery:
- Battery Type: Built-in rechargeable lithium battery
- Battery Capacity: 3.6V, 3000mAh
- Working Time: 10 hours
-
EtCO2/CO2
- EtC02/C02 Range: 0 - 150mmHg(0-20kPa, or 0-20%(V/V)
-
Accuracy:
- ± 2mmHg when 0 - 40mmHg
- ± 5% (reading) when > 41 - 70mmHg
- ± 8% (reading) when > 71 - 100mmHg
- ± 10% (reading) when> 101 - 150mmHg
- Update Selectable: Every breath, 10sec, 20sec or 30sec
- Trend Length: 24 hours
-
Respiration Rate:
- Range: 3 - 150t/min
- Accuracy: ± 1% (reading) or ± 1 times/min whichever is greater
- Trend Length: 24 hours
- Flux: 50 - 250 cc/min selectable
-
SpO2
- Oximetry Saturation Range: 0 - 100%
-
Accuracy:
- ± 2% when 70 - 100%
- ± 3% when 50 - 69%
- Trend Length: 24 Hours
-
Pulse Rate
- Range: 30 - 250 bpm
-
Accuracy:
- ± 2bpm or ± 2% (reading) when 30 - 250bpm
- Trend Length: 24 Hours
-
Power:
- AC Input: 100V-250V, 50Hz/60Hz
- AC Power Consumption: 5W
-
Operation
- Working temperature: 5 - 40 ºC
- Humidity: 30 - 75% (non-condensing)
- Atmospheric Pressure: 86 - 1 06kPa