Gastos estimados de envío
Descripción
The IKA C 200 Auto package runs the C 200 combustion calorimeter with a completely automated water cycle. The water circulates in a closed loop and is held at a constant temperature by a recirculating chiller, which shortens preparation time for each experiment and produces even more reproducible results. This makes the system especially convenient for laboratories that run a low number of analyses.
The semi-automated, standard-conforming calorimeter determines the gross calorific value of liquid and solid samples. Long used for teaching and training at technical schools and universities, the automated water handling now makes it suitable for industrial laboratories as well. Four operating modes — isoperibol, dynamic, manual, and time-controlled — let the user tune measurement times to individual requirements.
Key features:
- Fully automated closed-loop water handling with recirculating chiller
- Determines gross calorific value of liquid and solid samples
- Four operating modes: isoperibol, dynamic, manual, and time-controlled
- Shorter preparation time and improved reproducibility
- Complies with DIN 51900, ISO 1928, ASTM D240, D4809, D5865, D1989, D5468, and E711
- Optional C 6040 CalWin software for control, monitoring, and data export to Excel, Word, SQL, and LIMS
Package Includes:
- C 200 measuring cell
- C 5010 decomposition vessel
- C 200.RC set of hoses
- RC 2 GREEN basic recirculating chiller
- C 248 oxygen filling station
- Ignition adapter
- Water emptying hose
Country of Origin: Germany
Warranty: Comes with 2+1 Year Manufacturer's Warranty. See details here
Specifications:
| Measuring range max. | 40000 J |
| Measuring mode dynamic 25°C | yes |
| Measuring mode isoperibol 25°C | yes |
| Measuring time dynamic approx. | 8 min |
| Measuring time isoperibol approx. | 17 min |
| Reproducibility dynamic (1g benzoic acid NBS39i) | 0.1 %RSD |
| Reproducibility isoperibol (1g benzoic acid NBS39i) | 0.1 %RSD |
| Working temperature max. | 25 °C |
| Temperature measurement resolution | 0.0001 K |
| Cooling medium permissible operating pressure | 2 bar |
| Cooling medium | tap water |
| Type of cooling | flow |
| Chiller | RC 2 basic |
| Rec. flow rate at 18°C | 60 l/h |
| Oxygen operating pressure max. | 40 bar |
| Interface printer | Centronix |
| Interface PC | RS232 |
| Decomposition vessel C 5010 | yes |
| Works according to DIN 51900 | yes |
| Works according to DIN EN ISO 1716 | yes |
| Works according to DIN EN ISO 18125 | yes |
| Works according to DIN EN 15400 | yes |
| Works according to DIN CEN TS 14918 | yes |
| Works according to DIN CEN/TS 16023 | yes |
| Works according to DIN SPEC 19524 | yes |
| Works according to ASTM D240 | yes |
| Works according to ASTM D4809 | yes |
| Works according to ASTM D5468 | yes |
| Works according to ASTM D5865 | yes |
| Works according to ISO 1928 | yes |
| Works according to GOST Certified | yes |
| Dimensions (W x H x D) | 400 x 400 x 400 mm |
| Weight | 64.2 kg |
| Permissible ambient temperature | 20 - 25 °C |
| Permissible relative humidity | 80 % |
| Protection class according to DIN EN 60529 | IP 20 |
| RS 232 interface | yes |
| Voltage | 100 - 240 V |
| Frequency | 50/60 Hz |
| Power input | 120 W |