The Bionet® SPM-300 is a plug-in spirometer sensor that adds full pulmonary function testing to compatible Bionet instruments, including the Cardio 7 ECG and the SpiroCare pulmonary function monitor. Connect the handle, and the host device performs FVC, SVC and MVV tests, shows flow-volume and volume-time curves in real time on its color screen and prints a full-size report.
The SPM-300 is accurate and easy to maintain. It uses disposable SmarTube mouthpieces with a built-in sensor, so no part of the flow path is reused: there is nothing to disinfect between patients, and each test starts with a fresh, consistent sensor.
Key features:
- Adds spirometry to the Bionet Cardio 7 ECG; replacement sensor for SpiroCare (also compatible with Cardio Q50)
- Forced Vital Capacity (FVC), Slow Vital Capacity (SVC) and Maximum Voluntary Ventilation (MVV) tests
- Pre- and post-bronchodilator comparison
- Disposable SmarTube mouthpiece with built-in sensor - no disinfection needed between patients
- Real-time flow-volume and volume-time graphs on the host device's color display
- Full-size printouts and test storage on the host device
- Measurement accuracy complies with ATS standards
- Lightweight handheld design with handle dock
Package Includes:
- SPM-300 spirometer sensor (1 ea)
- SmarTube disposable mouthpieces (100 ea)
- Nose clip (1 ea)
- Mouthpiece adapter (1 ea)
- Handle dock (1 ea)
- Operation manual and diagnosis guide
ATS and ERS guidelines recommend daily calibration with a 3 L calibration syringe (SPM-CS, sold separately). Replacement SmarTube mouthpieces (SPM-MP, box of 100) are also available.
Country of Origin: South Korea
Warranty: Comes with a Complete 3-Year Manufacturer’s Warranty. See details here
Specifications:
| Tests | FVC, SVC, MVV; pre / post bronchodilator comparison |
| FVC parameters | FVC, FEV1.0, FEV1/FVC, FEF measures, PEF, FIVC, FEV6, PEFT, FET100% |
| SVC parameters | SVC, ERV, IRV, TV, EC |
| MVV parameters | MVV, breathing frequency (FB), tidal volume (TV) |
| Measuring method | Differential pressure |
| Measuring range | Flow 0 to ±14 L/s; volume 0 to ±12 L |
| Sample rate | 200 samples/sec |
| Flow impedance | < 0.2 mbar·s/L at 12 L/s |
| Accuracy | Complies with ATS standards |
| Prediction equations | Morris-Polgar, ECCS-Quanjer, Knudson-ITS, Pereira, Korea CJK |
| Operating environment | 15 - 40 °C, 10 - 90 % RH (non-condensing), 700 - 1060 hPa |
| Dimensions (W x D x H) | 1.85 x 1.34 x 7.87 in (47 x 34 x 200 mm) |
| Weight | Approx. 0.55 lb (250 g) |