SPM-300 is a spirometer sensor which works with the Cardio7-S and SpiroCare®. SPM-300 uses a disposable sensor, so it is very easy to maintain because the sensor does not require disinfecting between uses. These disposable sensors make an accurate measurement possible every time.
Features:
- Working with the Cardio7-S and SpiroCare
- FVC, SVC, and MVV test
- Pre- and post-bronchodilator comparison
- Disposable mouthpiece with patented sensing method
- No sensor cleaning required disinfecting between use
- Accurate and durable
Package Includes:
- Disposable moutpiece - 100 ea
- Nose clip - 1 ea
- Adapter - 1 ea
- Handle dock - 1 ea
- Operation manual - 1 ea
- Diagnosis guide - 1 ea
Country of Manufacture: South Korea
Warranty: Comes with 3 Years Manufacturer's Warranty
It is highly recommended to calibrate a spirometer with Bionet 3L Calibration Syringe periodically, in order to ensure accurate calibration of your spirometer.
Bionet's calibration recommendations are based upon guidelines from the American Thoracic Society (ATS) and the European Respiratory Society (ERS)
- The volume accuracy of the spirometer must be checked at least daily with a single discharge of a 3-L calibrated syringe.
- At least quarterly, volume spirometers must have their calibration checked over their entire volume range using a calibrated syringe or an equivalent volume standard. The measured volume should be within 3.5% of the reading or 65 mL, whichever is greater. This limit includes the 0.5% accuracy limit for a 3-L syringe.
Specifications:
Dimension | 47 (W) x 200 (H) x 34 (D)mm, approx. 250g |
Measuring Values | - FVC: FVC, FEV 1.0, FEV 1/FVC, FEF 0.2 - 1.2L, FEF 25 - 75%, FEF 75 - 85%, PEF, FEF 25%, FEF 50%, FEF 75%, FIVC, FEV6, PEFT, FET 100% - SVC: SVC, ERV, IRV, TV, EC - MVV: MVV, FB, TV |
Presentation | Flow volume loop MVV: MVV, FB, TV Measurement values table |
Measuring Range | Flow: 0 to ± 14 L/s Volume: 0 to ± 12 L |
Measuring Method | Differential pressure method |
Prediction Equation | Morris-Polgar, ECCS-Quanjer, Knudson-ITS, Pereira, Korea CJK |
Sample Rate | 200 samples/sec |
Flow Impedance | < 0.2 mbar s/l at 12 l/s |
Measuring Accuracy | Complies with ATS (American Thoracic Society) |
Environment | Ambient temperature: 15 to 40°C (59 to 104°F) Relative humidity: 10 to 90% (non-condensing) Atmospheric pressure: 700 to 1060 hPa |
Standard Accessories | Disposable moutpiece - 100 ea Nose clip - 1 ea Adapter - 1 ea Handle dock - 1 ea Operation manual - 1 ea |