Estimer la livraison
Description
The IKA C 6000 Isoperibol Oxygen Bomb Calorimeter combines advanced automation, flexibility, and modern technology in a single instrument. It operates in full compliance with major international standards including DIN, ISO, ASTM, GOST, and GB. Users can select from three starting temperatures (22°C, 25°C, or 30°C) across both measurement modes. A redesigned decomposition vessel helps reduce measurement time while improving sample handling and efficiency. With multiple interfaces—Ethernet, serial, USB, balance, and USB stick support—the system easily adapts to various laboratory workflows and can be integrated with data management and LIMS via C 6040 Calwin software.
Measuring Modes:
- Isoperibol
- Dynamic
Features
- Fully automatic ignition
- Automated water filling and draining
- Automated oxygen filling, venting, and flushing
- RFID-based automatic decomposition vessel identification
- Improved vessel design for faster and easier sample preparation
- Capacitive touchscreen operation for intuitive control
- Control chart display and correction functions for global standards
- Ethernet interface for network printer connectivity
- USB interface for data transfer and software updates
The C 6012 halogen-resistant decomposition vessel features a catalytically active inner surface, which enhances combustion reactions and improves recovery rates for halogens and sulfur compounds, increasing analytical accuracy.
Package Includes:
- C 6000 isoperibol
- C 6012 Decomposition vessel, halogen resistant
- RC 2 GREEN basic
Specifications:
| Measuring range max. | 40000 J |
| Measuring mode dynamic 22°C | yes |
| Measuring mode isoperibol 22°C | yes |
| Measuring mode dynamic 25°C | yes |
| Measuring mode isoperibol 25°C | yes |
| Measuring mode dynamic 30°C | yes |
| Measuring mode isoperibol 30°C | yes |
| Measurements/h dynamic | 6 |
| Measurements/h isoperibol | 4 |
| Reproducibility dynamic (1g benzoic acid NBS39i) | 0.15 %RSD |
| Reproducibility isoperibol (1g benzoic acid NBS39i) | 0.05 %RSD |
| Touchscreen | yes |
| Working temperature | 22 - 30 °C |
| Temperature measurement resolution | 0.0001 K |
| Cooling medium temperature | 12 - 27 °C |
| Cooling medium permissible operating pressure | 1.5 bar |
| Cooling medium | tap water |
| Type of cooling | flow |
| Chiller | RC 2 basic |
| Flow rate | 60 - 70 l/h |
| Rec. flow rate at 18°C | 60 l/h |
| Oxygen operating pressure max. | 40 bar |
| Interface scale | RS232 |
| Interface printer | USB |
| Interface PC | RS232 |
| Interface test rack | yes |
| Interface ext. keyboard | yes |
| Oxygen filling | yes |
| Degasification | yes |
| Decomposition detection | yes |
| Decomposition vessel C 6010 | yes |
| Decomposition vessel C 6012 | yes |
| Analysis according to DIN 51900 | yes |
| Analysis according to ASTM D240 | yes |
| Analysis according to ASTM D4809 | yes |
| Analysis according to ASTM D5865 | yes |
| Analysis according to ISO 1928 | yes |
| Analysis according to GB T213 | yes |
| Works according to DIN 51900 | yes |
| Works according to DIN EN ISO 1716 | yes |
| Works according to DIN EN ISO 9831 | yes |
| Works according to DIN EN ISO 18125 | yes |
| Works according to DIN EN 15170 | yes |
| Works according to DIN EN 15400 | yes |
| Works according to DIN CEN TS 14918 | yes |
| Works according to DIN CEN/TS 16023 | yes |
| Works according to DIN SPEC 19524 | yes |
| Works according to ASTM D240 | yes |
| Works according to ASTM D4809 | yes |
| Works according to ASTM D5468 | yes |
| Works according to ASTM D5865 | yes |
| Works according to ISO 1928 | yes |
| Works according to GB T213 | yes |
| Works according to GOST Certified | yes |
| Dimensions (W x H x D) | 500 x 425 x 450 mm |
| Weight | 29 kg |
| Permissible ambient temperature | 20 - 30 °C |
| Permissible relative humidity | 80 % |
| Protection class according to DIN EN 60529 | IP 20 |
| RS 232 interface | yes |
| USB interface | USB-B |
| Voltage | 115 V |
| Frequency | 50/60 Hz |
| Power input | 1700 W |
Country of Origin: Germany