Gastos estimados de envío
Payment & Security
Su información de pago se procesa de forma segura. No almacenamos los detalles de la tarjeta de crédito ni tenemos acceso a la información de su tarjeta de crédito.
Descripción
The C 1 static jacket oxygen bomb calorimeter represents a giant leap forward in calorimeter technology by featuring a high degree of automation in a compact design; the smallest calorimeter footprint available.
It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.
The traditionally known, comparably heavy screw threaded decomposition vessel, has been replaced by a light and easily attachable combustion chamber.
Due to the variety of different interfaces (PC, balance, printer) this unit is easily adaptable depending on the customer’s specific application needs. Further adaption to data management and LIMS is possible with our calorimeter software C 6040 Calwin (Accessory).
The C 1 Package 1/10 contains the C 1 Calorimeter (inclusive standard combustion chamber C 1.10) and the cooling water supply unit RC 2 basic.
The unit contains all parts necessary to set up the unit. We also supply wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The C 1.10 combustion chamber is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible.
Country of Origin: Germany
Warranty: Comes with 1+1 Year Warranty. See details here
Useable volume max. | 1000 ml |
Useable volume with disperser tool min. | 500 ml |
Working temperature max. | 120 °C |
Attainable vacuum | 25 mbar |
Viscosity max. | 100000 mPas |
Speed range | 10 - 150 rpm |
Support rod diameter (with integrated fastening on stand) | 16 mm |
Material in contact with medium | AISI 316L, 1.4571, borosilicate glass 3.3, PTFE, PEEK, FFKM |
Reactor vessel openings (units/standard) | 2x NS 29/32, 2x NS 14/23 & 2x GL 14 |
Permissible ON time | 100 % |
Temperature measurement resolution | 0.1 K |
Nominal torque | 3 Nm |
Heat output | 1000 W |
Cooling medium permissible operating pressure | 1 bar |
Weighing range max. | 2000 g |
Weighing resolution | 1 g |
pH measuring range | 0 - 14 pH |
pH measurement resolution | 0.1 pH |
Speed min (adjustable) | 10 rpm |
Heating temperature max. | 180 °C |
Adjustable safety circuit | 47 - 225 °C |
Adjustable safety circuit, temperature deviation | ±10 - ±20 K |
Cooling medium temperature min. | 3 °C |
Set temperature resolution | ±1 K |
Heat control accuracy of medium with sensor | ±0.2 K |
Speed deviation | ±5 rpm |
Speed display | TFT |
Heat control | TFT |
Connection for ext. temperature sensor | PT 100 |
Stirring element fastening | special output shaft |
Torque display | yes |
Torque measurement | trend |
Timer | yes |
Timer display | TFT |
Speed adjustment | 1 RPM steps |
Type of cooling | flow |
Temperature display | yes |
Working temperature sensor | PT 100 |
Safety temperature sensor | PT1000 |
Working temperature display | TFT |
Safety temperature display | TFT |
Display for operation with ext. sensor | yes |
Safety cutout | yes |
MV1 interface | yes |
pH meter interface | yes / BNC socket female |
pH value display | TFT |
Dimensions (W x H x D) | 443 x 360 x 295 mm |
Weight | 16 kg |
Permissible ambient temperature | 5 - 40 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 21 |
RS 232 interface | yes |
USB interface | yes |
Bluetooth interface | yes |
Voltage | 115 V |
Frequency | 50/60 Hz |
Power input | 1200 W |