Estimate shipping
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Description
The IKA C 3000 isoperibol calorimeter is the technologically advanced successor of the IKA C 2000 model, with great new features such as faster sample runs, a spherically shaped decomposition vessel for faster heat transfer and a convenient touch screen for easy operation. Both oxygen filling and water handling are fully automated.
Its measurements and calculations of net calorific value are according to ISO 1928, ASTM D4809, ASTM D5865, ASTM 240 and GB T213. Areas of application include the power and cement industry where accurate analyses are vital.
Features:
- Easy handling via touch screen operation or standard USB mouse
- Two choices of starting temperatures (22°C, 30°C)
- Automated ignition, water filling and draining and oxygen filling
- Several interfaces: Ethernet, RS 232, USB, SD card slot
- Six temperature sensors to monitor all temperatures allowing best analysis
- Spherically shaped decomposition vessel for better pressure stability and faster heat transfer
- Easy sample preparation due to new crucible holder technology
- Can be operated with a chiller (e.g. RC 2 basic)
Package Includes:
- C 3000 measuring cell
- C 6010 decomposition vessel, standard
- RC 2 basic recirculation chiller
- Wear parts and consumables for up to 500 tests
Country of Origin: Germany
Warranty: Comes with 1+1 Year Warranty. See details here
Measuring range max. | 40000 J |
Measuring mode dynamic 22°C | yes |
Measuring mode isoperibol 22°C | yes |
Measuring mode dynamic 30°C | yes |
Measuring mode isoperibol 30°C | yes |
Measurements/h dynamic | 6 |
Measurements/h isoperibol | 4 |
Reproducibility dynamic (1g benzoic acid NBS39i) | 0.15 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) | 0.05 %RSD |
Touchscreen | yes |
Working temperature | 22 - 30 °C |
Temperature measurement resolution | 0.0001 K |
Cooling medium temperature | 12 - 27 °C |
Cooling medium permissible operating pressure | 1.5 bar |
Cooling medium | tap water |
Type of cooling | flow |
Chiller | RC 2 basic |
Flow rate | 60 - 70 l/h |
Rec. flow rate at 18°C | 60 l/h |
Oxygen operating pressure max. | 40 bar |
Interface scale | RS232 |
Interface printer | USB |
Interface PC | RS232 |
Interface ext. keyboard | yes |
Oxygen filling | yes |
Decomposition vessel C 6010 | yes |
Decomposition vessel C 6012 | yes |
Analysis according to ASTM D240 | yes |
Analysis according to ASTM D4809 | yes |
Analysis according to ASTM D5865 | yes |
Analysis according to ISO 1928 | yes |
Analysis according to GB T213 | yes |
Dimensions (W x H x D) | 500 x 425 x 450 mm |
Weight | 29 kg |
Permissible ambient temperature | 20 - 30 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 20 |
RS 232 interface | yes |
USB interface | yes |
Voltage | 100 - 120 V |
Frequency | 50/60 Hz |
Power input | 1700 W |