Estimer la livraison
Politique de remboursement
Thank you for shopping with us at MedLabAmerica.com. We strive to provide you with the best possible customer service and want you to be completely satisfied with your purchase. In the event that you are not satisfied, we offer the following return policy:
Returns:
We accept returns on most items within 14 days after delivery. No returns accepted after 14 days. For your return to be eligible for a full refund (shipping charge is non-refundable), your item must be in the same condition as you received it, "unopened", unused" "in original packaging". *20% restocking fee will apply if the return is not in "Brand New" condition.
To initiate a return, please email us at info@medlabamerica.com with your order number and the reason for the return. Our customer service team will then provide you with a return authorization number and the address to send the item(s) back to. Please note that customers are responsible for the shipping cost of the return.
Non-Returnable Items: Certain items cannot be returned. (Please refer to the list below) Please note that all clearance and sale items are final sale and cannot be returned.
-
Opened or used equipment: Once equipment has been used or opened, it may be contaminated and unsuitable for resale.
- Clearance / Refurbished items: The items listed under our "Clearance Items" or "Refurbished Items" category are final sale. No returns accepted nor exchanges.
-
Consumable items: Items that are designed to be used once and then disposed of, such as disposable gloves, needles, and syringes, may not be eligible for return due to health and safety concerns.
-
Special order items: Items that are not regularly stocked and are specifically ordered for a customer are not eligible for return. If you believe that the product you are willing to purchase may fall into this category, please contact us first at 1-888-822 3336 or by email at info@medlabamerica.com before making your purchase to avoid any possible return issues.
-
Hazardous materials: Items that are classified as hazardous materials, such as chemicals or radioactive materials, may not be eligible for return due to safety concerns.
-
Software and digital media: Once software or digital media has been opened or activated, it may not be eligible for return due to licensing and copyright issues.
- Heavy equipment that require palletized shipment such as autoclaves, colposcopes, laboratory incubator shakers, industrial ultrasonic cleaners, heavy lighting fixtures, etc. For more information we recommend you to contact us for more details before you make a purchase
Items with a value exceeding $2,000 are subject to the manufacturer’s return policy. In such cases, return eligibility, restocking fees, and refund terms will be determined in accordance with the manufacturer’s guidelines.
Refunds:
Once we receive your item, we will inspect it and notify you that we have received your returned item. We will then process your refund and issue a credit to your original method of payment. Please allow 3-4 days for the refund to appear on your account.
Exchanges:
If you received a defective or damaged item, we will gladly exchange it for the same item. To initiate an exchange, please email us at info@medlabamerica.com with your order number and a photo of the damaged or defective item.
Order Cancellations:
We do not accept cancellations on orders once they are shipped. Undeliverable or refused shipments will be subject to a 25% restocking charge plus the cost of shipping and handling.
If you have any questions about our return policy, please contact us at info@medlabamerica.com. Thank you for shopping at medlabamerica.com
Description
The IKA C 6000 Global Standards Oxygen Bomb Calorimeter combines advanced technology, flexibility, and full automation in a single instrument. It complies with major international standards including DIN, ISO, ASTM, GOST, and GB.
Operators can select from three starting temperatures (22°C, 25°C, or 30°C) across all measuring modes. A redesigned decomposition vessel helps reduce measurement time while improving sample handling efficiency. With a wide range of interfaces—Ethernet, serial, USB, balance, and USB stick support—the system easily adapts to diverse laboratory requirements. Further integration with data management and LIMS is available via C 6040 Calwin software (accessory).
Measuring Modes:
- Adiabatic
- Isoperibol
- Dynamic
Features:
- Automatic ignition with ignition determination
- Fully automated water filling, draining, and oxygen handling (filling, venting, flushing)
- RFID-based automatic decomposition vessel identification
- Improved vessel design for faster and easier sample preparation
- Intuitive capacitive touchscreen operation
- Control chart display and correction for global standards
- Ethernet interface for network printer connection
- USB interface for data transfer and software updates
The C 6000 Global Standards Package consists of C 6000 global standards calorimeter and C 6012 halogen-resistant decomposition vessel featuring a catalytically active surface that enhances combustion reactions and improves recovery rates for halogens and sulfur compounds.
Package Includes:
- C 6000 global standards
- C 6012 Decomposition vessel, halogen resistant
Specifications:
| Measuring range max. | 40000 J |
| Measuring mode adiabatic 22°C | yes |
| Measuring mode dynamic 22°C | yes |
| Measuring mode isoperibol 22°C | yes |
| Measuring mode adiabatic 25°C | yes |
| Measuring mode dynamic 25°C | yes |
| Measuring mode isoperibol 25°C | yes |
| Measuring mode adiabatic 30°C | yes |
| Measuring mode dynamic 30°C | yes |
| Measuring mode isoperibol 30°C | yes |
| Measurements/h adiabatic | 5 |
| Measurements/h dynamic | 6 |
| Measurements/h isoperibol | 4 |
| Reproducibility adiabatic (1g benzoic acid NBS39i) | 0.05 %RSD |
| Reproducibility dynamic (1g benzoic acid NBS39i) | 0.15 %RSD |
| Reproducibility isoperibol (1g benzoic acid NBS39i) | 0.05 %RSD |
| Touchscreen | yes |
| Working temperature | 22 - 30 °C |
| Temperature measurement resolution | 0.0001 K |
| Cooling medium temperature | 12 - 27 °C |
| Cooling medium permissible operating pressure | 1.5 bar |
| Cooling medium | tap water |
| Type of cooling | flow |
| Chiller | RC 2 basic |
| Flow rate | 60 - 70 l/h |
| Rec. flow rate at 18°C | 60 l/h |
| Oxygen operating pressure max. | 40 bar |
| Interface scale | RS232 |
| Interface printer | USB |
| Interface PC | RS232 |
| Interface test rack | yes |
| Interface ext. keyboard | yes |
| Oxygen filling | yes |
| Degasification | yes |
| Decomposition detection | yes |
| Decomposition vessel C 6010 | yes |
| Decomposition vessel C 6012 | yes |
| Analysis according to DIN 51900 | yes |
| Analysis according to ASTM D240 | yes |
| Analysis according to ASTM D4809 | yes |
| Analysis according to ASTM D5865 | yes |
| Analysis according to ISO 1928 | yes |
| Analysis according to GB T213 | yes |
| Works according to DIN 51900 | yes |
| Works according to DIN EN ISO 1716 | yes |
| Works according to DIN EN ISO 9831 | yes |
| Works according to DIN EN ISO 18125 | yes |
| Works according to DIN EN 15170 | yes |
| Works according to DIN EN 15400 | yes |
| Works according to DIN CEN TS 14918 | yes |
| Works according to DIN CEN/TS 16023 | yes |
| Works according to DIN SPEC 19524 | yes |
| Works according to ASTM D240 | yes |
| Works according to ASTM D4809 | yes |
| Works according to ASTM D5468 | yes |
| Works according to ASTM D5865 | yes |
| Works according to ISO 1928 | yes |
| Works according to GB T213 | yes |
| Works according to GOST Certified | yes |
| Dimensions (W x H x D) | 500 x 425 x 450 mm |
| Weight | 29 kg |
| Permissible ambient temperature | 20 - 30 °C |
| Permissible relative humidity | 80 % |
| Protection class according to DIN EN 60529 | IP 20 |
| RS 232 interface | yes |
| USB interface | USB-B |
| Voltage | 115 V |
| Frequency | 50/60 Hz |
| Power input | 1700 W |
Country of Origin: Germany