Estimer la livraison
Payment & Security
Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.
Description
The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.
With the C 1 package 3/10 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21 °C: measuring mode 22 °C/ water temperature > 21 °C: measuring mode 30 °C). A chiller is no longer required.
The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.
Package Includes:
- C 1 calorimeter
- C 1.10 combustion chamber
- C 1.20 water heater
The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations.
Country of Origin: Germany
Warranty: Comes with 1+1 Year Warranty. See details here
Measuring range max. | 40000 J |
Measuring mode static jacket 22°C | yes |
Measuring mode static jacket 30°C | yes |
Measurements/h static jacket | 4 |
Reproducibility static jacke (1g benzoic acid NBS39i) | 0.15 %RSD |
Working temperature | 20 - 30 °C |
Temperature measurement resolution | 0.0001 K |
Cooling medium temperature | 18 - 29 °C |
Cooling medium permissible operating pressure | 1.5 bar |
Cooling medium | tap water |
Type of cooling | flow |
Flow rate | 50 - 60 l/h |
Rec. flow rate at 18°C | 55 l/h |
Oxygen operating pressure max. | 40 bar |
Interface scale | RS232 |
Interface printer | RS232 |
Interface PC | RS232 |
Oxygen filling | yes |
Degasification | yes |
Decomposition vessel integrated | yes |
Analysis according to DIN 51900 | yes |
Analysis according to ISO 1928 | yes |
Dimensions (W x H x D) | 290 x 280 x 300 mm |
Weight | 15 kg |
Permissible ambient temperature | 5 - 40 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 20 |
RS 232 interface | yes |
USB interface | yes |
Voltage | 100 - 240 V |
Frequency | 50/60 Hz |
Power input | 120 W |