{"product_id":"bionet-cardio-q50-12ch-resting-ecg","title":"Bionet® Cardio Q50 12Ch. Resting ECG, Cardio Q50","description":"\u003cp\u003eThe \u003cstrong\u003eBionet® Cardio Q50\u003c\/strong\u003e is a 12-channel interpretive \u003cstrong\u003eresting ECG\u003c\/strong\u003e built around an \u003cstrong\u003e8\" capacitive color touch screen\u003c\/strong\u003e that stays responsive through medical gloves. It acquires all twelve leads simultaneously at an 8,000 Hz digital sampling rate and interprets them with both the Bionet algorithm and the \u003cstrong\u003eUniversity of Glasgow algorithm\u003c\/strong\u003e, which weighs age, gender and race and is highly effective in STEMI interpretation.\u003c\/p\u003e\n\u003cp\u003eA single \u003cstrong\u003eAUTO\u003c\/strong\u003e key runs the whole study — acquisition, analysis, documentation, storage, printout and export — in about three seconds. Beyond the standard 10-second record the Cardio Q50 offers \u003cstrong\u003e30-minute full disclosure\u003c\/strong\u003e with real-time arrhythmia detection and side-by-side comparison against the patient's previous ECG. Reports print on the built-in thermal recorder in A4 or Letter format, or leave the device entirely as PDF, XML, MFER, BMP, JPG or DICOM over LAN or optional Wi-Fi. The device is \u003cstrong\u003espirometry-ready\u003c\/strong\u003e: adding the SPM-300 USB handle turns it into a combined ECG and pulmonary function workstation that stores both results under one patient record.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top:0;margin-bottom:0;padding-left:20px\"\u003e\n\u003cli style=\"line-height:1.4\"\u003e8\" wide capacitive color touch screen (1,024 x 600) that responds through medical gloves\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eSimultaneous 12-channel acquisition at an 8,000 Hz digital sampling rate\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eTwo interpretation algorithms: the Bionet algorithm and the University of Glasgow algorithm, which accounts for age, gender and race\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eOne-touch AUTO key: acquisition, analysis, documentation, storage, printout and export in about 3 seconds\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003e30-minute full-disclosure recording with real-time arrhythmia detection and live comparison against a previous ECG\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003e120 interpretation statements, plus HRV trend analysis from a single command\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eBuilt-in memory for 500 ECG records; USB flash-drive storage and USB barcode-reader support\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eBuilt-in thermal recorder printing half-A4 or half-Letter reports, with Text, Guide and Vector beat formats\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003ePaperless export in PDF, XML, MFER, BMP, JPG and DICOM for EMR, HIS and PACS systems\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eLAN and optional Wi-Fi transmission, plus HDMI output for a large-screen display\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eSpirometry-ready: an external USB handle adds COPD, FVC, SVC and MVV test modes, stored alongside the patient's ECG data\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eReplaceable Li-ion battery giving approximately 10 hours of use or 350 printed ECGs, recharging in about 3 hours\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eHIPAA-oriented security: encrypted patient data, per-user IDs, roles and passwords, event log, auto standby and shutdown, and patient-name masking on printouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top:0;margin-bottom:0;padding-left:20px\"\u003e\n\u003cli style=\"line-height:1.4\"\u003eCardio Q50 main unit (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003e10-lead ECG patient cable (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eECG alligator clips (1 set)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eDisposable ECG electrodes (1 set)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eMedi-Graph ECG recording paper (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eHospital-grade power cord (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eRechargeable Li-ion battery, 10.8 V \/ 6,500 mAh (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eUSB Wi-Fi dongle (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eECG gel (1 ea)\u003c\/li\u003e\n\u003cli style=\"line-height:1.4\"\u003eOperation manual, ECG diagnosis guide and quick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cem\u003eOptional accessories: SPM-300(U) spirometer sensor handle, SmarTube disposable mouthpieces, 3 L calibration syringe, PFT filters, spare ECG-BAT-Q battery, folded A4 Medi-Graph paper, ECG cart with cable hanger, touch screen stylus and ECG gel.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e South Korea\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e Comes with a Complete 3-Year Manufacturer’s Warranty. See details \u003ca href=\"https:\/\/bionetus.com\/medical\/service-support\/warranty-registration\/\" target=\"_blank\" rel=\"noopener\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eECG leads\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSimultaneous 12-channel acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRecording formats\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e3CH+3RHY, 3CH+1RHY, 6CH+1RHY, 12CH, 1CH+3, Cabrera report; 1-channel long recording (1, 3, 5, 10, 20, 30 min); beat reports (Text, Guide, Vector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eGain\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e2.5, 5, 10, 20 mm\/mV, Auto (I - aVF: 10, V1 - V6: 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePrinting speed\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e5, 12.5, 25, 50, 100 mm\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSampling rate\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eAnalysis 500 Hz; digital 8,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eFilters\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eAC 50\/60 Hz (-20 dB or better); muscle 25 - 35 Hz (-3 dB or better); baseline drift 0.05 \/ 0.1 \/ 0.2 Hz (-3 dB or better); low pass off \/ 40 \/ 100 \/ 150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eInterpretation\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eBionet ECG analysis algorithm and the University of Glasgow ECG analysis algorithm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eBasic measurement\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eHeart rate 30 - 300 bpm (±3 bpm), PR\/RR interval, QRS duration, QT\/QTc interval, P-R-T axis, SV1\/RV5\/R+S amplitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePatient data fields\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eID, name, date of birth, age, gender, height, weight, race, smoking status, department, room no., study description, accession no., referring physician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eInternal noise 20 µV (p-p) max; input impedance ≥ 50 MΩ; input voltage range ±5 mV; CMRR \u0026gt; 105 dB; DC offset voltage ≥ ±400 mV; patient leakage current \u0026lt; 10 µA; frequency response 0.05 - 200 Hz within -3 dB; isolated, defibrillation and ESU protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSignal quality control\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePacemaker pulse detection, lead-fault detection, signal-saturation detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSpirometry test modes (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCOPD, FVC, FEV1\/FEV6, SVC, MVV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSpirometry measured values (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eFVC: FVC, FEV1, FEV1\/FVC, FEF 0.2-1.2 L, FEF 25-75 %, FEF 75-85 %, PEF, FEF 25 %, FEF 50 %, FEF 75 %, FIVC, FEV6, PEFT, FET 100 %, extrapolation volume. FEV1\/FEV6: FEV1, FEV6, FEV1\/FEV6, LFI. SVC: SVC, TV, ERV, IRV, EC. MVV: MVV, FB, TV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSpirometry presentation (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eFlow volume loop, volume time graph, measurement values table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSpirometry measuring range (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eFlow 0 to ±14 L\/s; volume 0 to ±12 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSpirometry method (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eDifferential pressure, 200 samples\/sec; flow impedance \u0026lt; 0.2 mbar s\/L at 12 L\/s; complies with ISO 26782 and ISO 23747\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePrediction equations (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMorris-Polgar, Knudson-ITS, ECCS-Quanjer, Korea CJK, Pereira, GLI-2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSpirometer handle (option)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e48 x 39 x 201 mm; approx. 250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e8\" color TFT wide display (1,024 x 600) with 12-channel ECG preview\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eUser interface\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eTouch screen with alphanumeric and symbol entry, function keys, keyboard (option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eData storage\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eBuilt-in memory for 500 ECG records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePrinter\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eThermal print head, Z-fold paper; report paper A4 210 x 300 mm (8.3 x 11.8\") or Letter 215 x 280 mm (8.5 x 11\"); resolution 8 dot\/mm vertical, 16 dot\/mm horizontal (0.125 mm pitch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eExport formats\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePDF, XML, MFER, BMP, JPG, DICOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCommunication\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLAN, Wi-Fi (option), USB flash drive, USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eInput 100 - 240 VAC, 50\/60 Hz, 1.5 - 0.75 A; output 15 VDC, 4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eBattery\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eReplaceable rechargeable lithium-ion, 10.8 V, 6,500 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eBattery capacity\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eApprox. 10 hours of normal use or 350 printed 12-channel ECGs; full recharge in approx. 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSafety conformity\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eClass I; Type CF applied parts (ECG electrodes); Type B applied part (spirometer handle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e10 to 40 °C; 30 to 85 % relative humidity; 700 to 1060 hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eStorage \/ shipping\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e-20 to 60 °C; 10 to 95 % relative humidity; 500 to 1060 hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e286 x 350 x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eApprox. 4.5 kg (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:6px 0\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/CardioQ50_ECG_EKG_Brochure.pdf?v=1793317764\" target=\"_blank\" rel=\"noopener\"\u003eProduct Brochure\u003c\/a\u003e  |  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/CardioQ50_ECG_EKG_User_Manual.pdf?v=1793317765\" target=\"_blank\" rel=\"noopener\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Bionet America","offers":[{"title":"Default Title","offer_id":50608502079626,"sku":"CARDIO Q50","price":2450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Bionet_Cardio_Q50_ECG_front.png?v=1793317782","url":"https:\/\/medlabamerica.com\/products\/bionet-cardio-q50-12ch-resting-ecg","provider":"MedLabAmerica.com","version":"1.0","type":"link"}