{"product_id":"accuris-smartreader-multimode-microplate-reader-mr9620","title":"Accuris™ SmartReader™ MultiMode Microplate Reader, Absorbance, Fluorescence \u0026 Luminescence, MR9620","description":"\u003cp\u003eThe Accuris™ MR9620 SmartReader™ MultiMode Plate Reader is an all-in-one microplate reader for absorbance, fluorescence and luminescence, built to meet the growing needs of advanced life science laboratories. It reads standard 96-well plates as well as 6-, 12-, 24-, 48- and 384-well plates, and is programmed and operated entirely from its large 10-inch color touch screen — no external computer or software is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUV-Visible absorbance:\u003c\/strong\u003e an advanced monochromator and long-life, broad-spectrum xenon flash lamp deliver any wavelength from 200 to 1000 nm in 1 nm steps, reading a full 96-well plate in under 15 seconds. Kinetic assays display a curve for every well in real time, and the optional SmartDrop™ plate (MR9610-SDP) measures up to 16 nucleic acid or protein droplets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluorescence:\u003c\/strong\u003e three filter modules covering the most common excitation\/emission pairs are included, and additional modules are available. The modules combine dichroic mirrors with narrow band-pass filters for high light transmission and sensitivity, are easily exchanged, and are barcoded so wavelength data load automatically. Automatic dynamic range selection adjusts PMT gain to capture and normalize signal intensity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLuminescence:\u003c\/strong\u003e an advanced PMT handles both flash and glow assays, enhancing weak signals while preventing saturation of strong ones. Up to two sample injectors (available separately) can be installed and work with 96- and 384-well plates.\u003c\/p\u003e\n\u003cp\u003eA built-in shaker offers linear, orbital and double-orbital modes, and top-heating incubation from ambient +4°C to 45°C creates a gradient that prevents condensation on lidded plates. At start-up the reader runs a self-diagnostic and automatic calibration of the whole system. Data export as .XLS or .CSV via the included USB flash drive or FTP server, or through the optional SmartReader™ PC Software (research version MR9620-PC, or FDA 21 CFR Part 11 compliant version MR9620-CFR).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eELISA and colorimetric assays (Bradford, Lowry and more)\u003c\/li\u003e\n\u003cli\u003eEnzyme kinetics and spectral scanning\u003c\/li\u003e\n\u003cli\u003eDNA and RNA analysis\u003c\/li\u003e\n\u003cli\u003eFluorescence intensity assays\u003c\/li\u003e\n\u003cli\u003eFlash and glow luminescence assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAbsorbance, fluorescence and luminescence in one instrument\u003c\/li\u003e\n\u003cli\u003eIntuitive 10-inch color touch screen; stand-alone operation\u003c\/li\u003e\n\u003cli\u003eMonochromator absorbance, 200–1000 nm in 1 nm steps\u003c\/li\u003e\n\u003cli\u003eBarcoded, interchangeable fluorescence filter modules (3 included)\u003c\/li\u003e\n\u003cli\u003ePMT luminescence detection for flash and glow assays\u003c\/li\u003e\n\u003cli\u003eAccepts 6- to 384-well plates\u003c\/li\u003e\n\u003cli\u003eLinear, orbital and double-orbital shaking; top-heated incubation to 45°C\u003c\/li\u003e\n\u003cli\u003eOptional PC software, including FDA 21 CFR Part 11 version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAccuris™ SmartReader™ MultiMode MR9620\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eMeasurement Technologies\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance, fluorescence, luminescence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePlate Formats\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e6- to 384-well plates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eShaking\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLinear (4.7, 7.0, 13.5 Hz), orbital and double orbital (240–1,200 rpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eIncubation Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAmbient +4°C to 45°C (top heating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e10-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2 USB-A, 1 USB-B, 1 Ethernet, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePower Input\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e100–240V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e42.0 x 55.0 x 38.6 cm (16.5 x 21.7 x 15.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e33 kg (72.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAbsorbance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eHigh-energy xenon flash lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePhotodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e200–1000 nm, 1 nm steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWavelength Accuracy \/ Repeatability\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2 nm \/ 0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eBandwidth (FWHM)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.0–4.0 OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.0001 OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAccuracy (96-well, precision mode)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e±(1.0% + 0.003 Abs) at 0.0–2.0 Abs; ±2.0% at 2.0–3.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCV \u0026lt;1.0% or SD \u0026lt;0.003 (fast); CV \u0026lt;0.5% or SD \u0026lt;0.003 (accurate), 0.0–3.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eStray Light\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.1% at 220 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLinearity\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eR² \u0026gt;0.999 at 0.0–3.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u0026lt;15 seconds per 96-well plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eFluorescence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eReading Mode\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eTop reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eExcitation Light Source\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eHigh-energy xenon flash lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePhotomultiplier tube (PMT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e≤1 pM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eEX 200–1000 nm; EM 270–850 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eIncluded Filter Modules (EX\/EM)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e485\/530 nm; 523\/564 nm; 624\/692 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLinear Dynamic Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e6 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eLuminescence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePhotomultiplier tube (PMT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e15 amol\/well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLinear Dynamic Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e6 logs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eInjectors\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUp to 2 optional automatic injection modules (MR9620-AIM1 \/ -AIM2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/01\/MR9620-Literature-EMV1.2.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartReader MultiMode Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2023\/11\/MR9620-Operation-Manual-V1.0.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris MR9620 SmartReader MultiMode Operation Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"US Plug - 115V","offer_id":72015749808266,"sku":"MR9620","price":25026.83,"currency_code":"USD","in_stock":true},{"title":"EU Plug - 230V","offer_id":72015749841034,"sku":"MR9620-E","price":25026.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Accuris-MR9620-SmartReader-MultiMode-Plate-Reader.jpg?v=1794445518","url":"https:\/\/medlabamerica.com\/products\/accuris-smartreader-multimode-microplate-reader-mr9620","provider":"MedLabAmerica.com","version":"1.0","type":"link"}