{"product_id":"accuris-smart-q-800-fluorometer-8-channel-f1008","title":"Accuris™ Smart-Q™ 800 Fluorometer, 8-Channel, DNA\/RNA\/Protein Quantification, F1008","description":"\u003cp\u003eThe Accuris™ Smart-Q™ 100 and Smart-Q™ 800 fluorometers are designed for precise quantification of DNA, RNA and protein samples. Using well-established fluorescence detection methods, the Smart-Q fluorometers provide higher specificity and accuracy than traditional UV-absorbance detection — particularly important in workflows such as next-generation sequencing, PCR, transfection, Western blotting and immunoassays. They are optimized for Accuris fluorescent quantification kits and assay tubes, and are also compatible with kits from other suppliers.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart-Q™ 800\u003c\/strong\u003e is built for higher-throughput workflows: up to eight samples are read at once in individual 0.2 ml tubes (F1008-T) or 8-tube 0.2 ml strips (F1008-T-8). A standard 8-channel pipette can be used for both reagent preparation and sample transfer, making the Smart-Q™ 800 an efficient solution for parallel processing of multiple samples.\u003c\/p\u003e\n\u003cp\u003eEach instrument has a 7-inch color touch screen with an intuitive, icon-driven interface. Preprogrammed protocols allow quick assay set-up, built-in reagent calculators help with sample preparation, and results are calculated and displayed in under 6 seconds, saved to internal memory and easily exported to a PC by USB flash drive. Advanced curve-fitting algorithms build calibration curves from 2–3 standards of known concentration, and unknown concentrations are determined by correlating their relative fluorescence units (RFUs) with the standards. Blue and red channels allow a variety of fluorescent dyes to be used for nucleic acid and protein measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSensitive quantification down to 0.1 pg\/µl dsDNA\u003c\/li\u003e\n\u003cli\u003e7-inch color touch screen with icon-driven menus\u003c\/li\u003e\n\u003cli\u003eBlue and red excitation channels for DNA, RNA and protein dyes\u003c\/li\u003e\n\u003cli\u003eBuilt-in reagent calculators for sample preparation\u003c\/li\u003e\n\u003cli\u003eResults in seconds; internal memory and USB export\u003c\/li\u003e\n\u003cli\u003eCompact and portable, 11 x 6 inch footprint\u003c\/li\u003e\n\u003cli\u003eReads up to 8 samples at once in 0.2 ml tubes or 8-tube strips\u003c\/li\u003e\n\u003cli\u003eLoad directly with an 8-channel pipette\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConsumables: \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smart-q-fluorescence-assay-tubes\"\u003eSmart-Q™ assay tubes\u003c\/a\u003e and \u003ca href=\"https:\/\/medlabamerica.com\/search?q=Accuris+Quantification+Kit\"\u003eAccuris DNA\/RNA quantification kits\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAccuris™ Smart-Q™ 800, F1008\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e7.0-inch color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDynamic Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e4 orders of magnitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eBlue LED and red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eExcitation Wavelengths\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eBlue: 460 ± 20 nm; Red: 625 ± 20 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eEmission Wavelengths\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eGreen: 525–570 nm; Red: 670–725 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eStability\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePhotodiodes (300–1,000 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e≤ 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2–3-point standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eConsumables\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.2 ml assay tubes (single and 8-tube strip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e24 VDC, 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e16.1 x 28.7 x 7.6 cm (6.3 x 11.3 x 3.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2.0 kg (4.4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/11\/F1001_F1008-Literature-2025.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris Smart-Q 100 and 800 Brochure\"\u003eSmart-Q Brochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/F1008-User-Manual-V1.1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris Smart-Q 800 F1008 Instruction Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/11\/Accuris-Quantification-Kits-Brochure-.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris Quantification Kits Brochure\"\u003eQuantification Kits Brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"US Plug - 115V","offer_id":72016352051338,"sku":"F1008","price":6868.33,"currency_code":"USD","in_stock":true},{"title":"EU Plug - 230V","offer_id":72016352084106,"sku":"F1008-E","price":6868.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Accuris-Smart-Q-Fluorometers-Pair.jpg?v=1794451863","url":"https:\/\/medlabamerica.com\/products\/accuris-smart-q-800-fluorometer-8-channel-f1008","provider":"MedLabAmerica.com","version":"1.0","type":"link"}