{"product_id":"leisegang-optik-model-1-led-colposcope-1dl-led","title":"Leisegang® OptiK® Model 1 LED Colposcope (1DL LED)","description":"\u003cp\u003eThe Leisegang OptiK Model 1 is a German-engineered LED colposcope for routine magnified examination of the cervix, vagina and vulva. It offers three-step magnification and bright LED illumination in a choice of mounting bases to suit the exam room.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3-step magnification\u003c\/li\u003e\n\u003cli\u003e300 mm working distance\u003c\/li\u003e\n\u003cli\u003eLED illumination, 24,000 lux (1DL LED)\u003c\/li\u003e\n\u003cli\u003eBase selectable: tilt base, upright rolling base, medium-weight swing-arm rolling base or heavy-weight Balance-O-Matic rolling base\u003c\/li\u003e\n\u003cli\u003eNon-photo model\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLeisegang 1DL-LED (non-photo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eOptics\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eConvergent stereoscopic optics with parfocal 3-step drum changer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMagnification\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e3.75x, 7.5x, 15x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eField of view\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e76 mm, 38 mm, 19 mm (by magnification step)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWorking distance\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eEyepieces\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eIndividually adjustable, +7 to -7 diopters; measuring reticules in the left optical path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eFilter\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eGreen filter for vascular contrast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eIllumination\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eIntegrated LED, 23,000 to 35,000 lx at 300 mm; 5,700 to 6,000 K; CRI 92; 78 mm light field; rated life at least 10,000 h (about 20,000 h typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e100-240 V~, 50\/60 Hz, 2 A max input; output 3.2 V \/ 3 A; LED 10 W; fuses 5 × 20 mm, 2 A time-lag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eClassification\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eProtection Class II (no ground required), IP20, no applied parts, continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eStandards\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eAAMI\/ANSI ES 60601-1, IEC 60601-1-2, IEC 60601-2-41, CAN\/CSA C22.2 No. 60601.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eComponent weights\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eHead 3.5 kg; LED power supply 0.5 kg; tilt stand 3.0 kg; upright stand 7.0 kg; swing stand 7.0 kg; Balance-O-Matic with weighted base 24.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e10 to 45 °C, 30 to 75% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eBase options\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eOPTIK1-00: tilt base (flat, stationary, 30 × 30 cm footprint); OPTIK1-01: upright roller base; OPTIK1-02: swing base with manual height adjustment on 5-wheel locking base; OPTIK1-03: Balance-O-Matic counterbalanced arm with locking lever on heavy 5-wheel base (roller bases 65 × 65 cm footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Leisegang-OptiK-Colposcope-IFU-Rev-D.pdf?v=1794788588\" target=\"_blank\" rel=\"noopener\"\u003eProduct Manual (OptiK IFU)\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Leisegang-Colposcope-and-Accessories-Instructions-for-Use.pdf?v=1794788588\" target=\"_blank\" rel=\"noopener\"\u003eProduct Manual (Colposcope \u0026amp; Accessories)\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Leisegang-Product-Catalog-2025.pdf?v=1794788589\" target=\"_blank\" rel=\"noopener\"\u003eProduct Catalog\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Cooper Surgical","offers":[{"title":"Tilt Base","offer_id":72053895692426,"sku":"OPTIK1-00","price":10670.07,"currency_code":"USD","in_stock":true},{"title":"Upright Rolling Base","offer_id":72053895725194,"sku":"OPTIK1-01","price":10670.07,"currency_code":"USD","in_stock":true},{"title":"Swing-Arm Rolling Base","offer_id":72053895757962,"sku":"OPTIK1-02","price":11855.62,"currency_code":"USD","in_stock":true},{"title":"Balance-O-Matic Rolling Base","offer_id":72053895790730,"sku":"OPTIK1-03","price":14490.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/LEISEGANG-OPTIK_C2_AE-MODEL-1-COLPOSCOPE.jpg?v=1794627680","url":"https:\/\/medlabamerica.com\/fr\/products\/leisegang-optik-model-1-led-colposcope-1dl-led","provider":"MedLabAmerica.com","version":"1.0","type":"link"}