{"product_id":"wallach-ll100-llco2-multi-tip-cryosurgical-freezer","title":"Wallach® LL100™\/LLCO2™ Multi-Tip Cryosurgical Freezer","description":"\u003cp\u003eThe Wallach LL100 and LLCO2 are handheld, multi-tip cryosurgical freezers used in gynecology and dermatology offices for controlled freezing of benign and pre-malignant lesions. Choose the LL100 for nitrous oxide (N2O) or the LLCO2 for medical-grade carbon dioxide; both connect directly to a standard 20 lb. gas cylinder and accept the full line of interchangeable Wallach cryotips.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas configuration selectable: LL100 (N2O, item 900001) or LLCO2 (CO2, item 900160)\u003c\/li\u003e\n\u003cli\u003eIncludes the cylinder connection for 20 lb. tanks\u003c\/li\u003e\n\u003cli\u003eLL100 uses a two-trigger design with separate freeze and defrost control\u003c\/li\u003e\n\u003cli\u003eLLCO2 is a single-trigger system designed to limit the clogging and sputtering associated with CO2\u003c\/li\u003e\n\u003cli\u003eUses standard Wallach cryotips with disposable plastic shields (sold separately)\u003c\/li\u003e\n\u003cli\u003eFreezer only; gas cylinder and tips are not included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with Wallach cryotips, 900221AA disposable tip shields and Wallach 20 lb. cylinder carts.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFreezer handle and probe with attached gas hose\u003c\/li\u003e\n\u003cli\u003ePressure gauge block with cylinder connector\u003c\/li\u003e\n\u003cli\u003eTip holder\u003c\/li\u003e\n\u003cli\u003eGas cylinder and cryotips sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eModels\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e900001: LL100 for nitrous oxide (N2O); 900160: LLCO2 for carbon dioxide (CO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eTrigger design\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLL100: two triggers, separate freeze and defrost; LLCO2: single trigger (squeeze to freeze, release to defrost; can be locked forward during a freeze)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eGas\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMedical-grade N2O (LL100) or medical-grade CO2 (LLCO2) only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eGas supply\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e20 lb (9 kg) cylinder, not included; cylinder must hold no more than 9 kg (19.8 lb) of liquid gas and at least 1.36 kg (3 lb) to start a procedure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCylinder connection\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLL100: handwheel connector on pressure gauge block; LLCO2 (900160): handwheel yoke, CGA 320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eOperating pressure (LLCO2)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e650 to 800 psi (45.7 to 56.25 kg\/cm²) on the built-in gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eOverpressure protection (LL100)\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSingle-use rupture disk vents gas if cylinder pressure reaches 1500 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eTypical freeze time\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e1 to 3 minutes per application (LLCO2 directions for use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRecommended operating temperature\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eUnit and cylinder at room temperature, 18 to 22 °C (68 to 74 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eGas scavenging\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eExhaust port on gauge block accepts a scavenger hose of at least 6 mm ID (Wallach 901015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLLCO2 dimensions \/ weight\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e18.9 × 11.5 × 5.2 in (48 × 29.2 × 13.2 cm); 5 lb (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCompatible tips\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eAll Wallach reusable cryotips 900200AA to 900217AA and 900300AA to 900306AA, used with 900221AA disposable shields\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCleaning\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWipe handle, silicone hoses, gauge block and connector with disinfectant; high-level disinfect the insulation probe by wrapping; no heat, soaking or steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLL100: 5 years (1 year unconditional plus 4 years parts and labor for manufacturing defects); LLCO2: 5 years against defects in material and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRx only; LL100 labeled latex-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Wallach-LL100-Cryosurgical-Unit-Instructions-for-Use.pdf?v=1794788588\" target=\"_blank\" rel=\"noopener\"\u003eProduct Manual (LL100)\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Wallach-LLCO2-Cryosurgical-System-Instructions-for-Use.pdf?v=1794788588\" target=\"_blank\" rel=\"noopener\"\u003eProduct Manual (LLCO2)\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/www.coopersurgical.com\/wp-content\/uploads\/2026\/10\/CSI_Clinic-Catalog_2026_v4.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Catalog\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Wallach Surgical","offers":[{"title":"N2O - LL100 (20 lb. cylinder connection)","offer_id":72053893267594,"sku":"900001","price":2655.62,"currency_code":"USD","in_stock":true},{"title":"CO2 - LLCO2 (20 lb. cylinder connection)","offer_id":72053893300362,"sku":"900160","price":2950.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/72f76910-862f-4739-9bca-4fdbd2837c28mediumLL100.jpg?v=1794627668","url":"https:\/\/medlabamerica.com\/es\/products\/wallach-ll100-llco2-multi-tip-cryosurgical-freezer","provider":"MedLabAmerica.com","version":"1.0","type":"link"}