{"title":"Fetal Monitor \u0026 Doppler Accessories | MedLabAmerica.com","description":"\u003cp\u003eTransducers, TOCO probes, belts, thermal paper, carts, batteries, interchangeable doppler probes and ultrasound gel for fetal monitors and obstetric dopplers.\u003c\/p\u003e","products":[{"product_id":"coopersurgical-f9-fetal-monitor-accessories","title":"Cooper Surgical® F9 Fetal Monitor Accessories","description":"\u003cp\u003eGenuine replacement parts and accessories for the CooperSurgical F9 fetal monitor. Use them to replace worn transducers and belts, restock recording paper, or add mobility and battery operation to your F9 setup. Select the item you need from the options.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUltrasound transducer 1 (pink) and transducer 2 (yellow) for twin FHR monitoring\u003c\/li\u003e\n\u003cli\u003eTOCO transducer (blue) for uterine activity\u003c\/li\u003e\n\u003cli\u003ePatient event marker\u003c\/li\u003e\n\u003cli\u003eReusable transducer belt (sold individually)\u003c\/li\u003e\n\u003cli\u003eRecording paper, 90 mm x 152 mm x 150 pages, pack of 3\u003c\/li\u003e\n\u003cli\u003eRechargeable lithium battery and rolling cart options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with the CooperSurgical F9 fetal monitor. Check your monitor's transducer connector (4-pin or 6-pin) before ordering.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eM21-64072 battery\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e14.8 V, 4400 mAh rechargeable lithium-ion; about 2–4 hours of operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMS3-31528-A1 \/ MS3-107705-A1 transducers\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eUltrasound channel 1 (pink) \/ channel 2 (yellow); 1.0 MHz pulsed-wave, 12-crystal; 88 × 35 mm; 190 g; 2.5 m (8 ft) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMS3-31527-A1 TOCO probe\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eExternal uterine activity, 0–100% range; 88 × 35 mm; 180 g; 2.5 m (8 ft) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMS3-31112 event marker\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eHand-held patient marker; 56 g; 2.5 m (8 ft) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMS1R-02264 belt\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eReusable, washable transducer belt; sold singly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eM25R-75111 paper\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eZ-fold thermal paper, 90 × 152 mm × 150 pages, US standard; 3 per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMS9-108108 \/ MS9-108166 basic carts\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRolling cart with wire storage basket and casters; MS9-108166 adds a laptop tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eMS9-107634 deluxe cart\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRolling cart with storage, four casters and a secure monitor mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCooperSurgical F9 fetal monitor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eTransducers, TOCO, event marker, belt: 90 days; carts: 1 year; paper: 90 days or until expiration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Cooper Surgical","offers":[{"title":"Rechargeable Lithium Battery","offer_id":72053900968074,"sku":"M21-64072","price":565.69,"currency_code":"USD","in_stock":true},{"title":"Deluxe Cart","offer_id":72053901000842,"sku":"MS9-107634","price":1419.08,"currency_code":"USD","in_stock":true},{"title":"Basic Cart with Basket","offer_id":72053901033610,"sku":"MS9-108108","price":1006.7,"currency_code":"USD","in_stock":true},{"title":"Basic Cart with Basket \u0026 Laptop Tray","offer_id":72053901066378,"sku":"MS9-108166","price":1029.15,"currency_code":"USD","in_stock":true},{"title":"Ultrasound Transducer 1 (Pink, 4-pin)","offer_id":72053901099146,"sku":"MS3-31528-A1","price":791.48,"currency_code":"USD","in_stock":true},{"title":"Ultrasound Transducer 2 (Yellow, 4-pin)","offer_id":72053901131914,"sku":"MS3-107705-A1","price":791.46,"currency_code":"USD","in_stock":true},{"title":"TOCO Transducer (Blue)","offer_id":72053901164682,"sku":"MS3-31527-A1","price":643.08,"currency_code":"USD","in_stock":true},{"title":"Event Marker","offer_id":72053901197450,"sku":"MS3-31112","price":86.44,"currency_code":"USD","in_stock":true},{"title":"Transducer Belt (single, reusable)","offer_id":72053901230218,"sku":"MS1R-02264","price":18.31,"currency_code":"USD","in_stock":true},{"title":"Recording Paper 90mm x 152mm x 150p, Pack of 3","offer_id":72053901262986,"sku":"M25R-75111","price":40.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/e64051e5-5b23-4001-9d4b-b4f4b40381e9mediumf9-cart.jpg?v=1794779803"},{"product_id":"wallach-fetal2emr-fetal-monitor-accessories","title":"Wallach® FETAL2EMR™ Fetal Monitor Accessories","description":"\u003cp\u003eReplacement parts and accessories for the Wallach FETAL2EMR fetal monitor, from transducers and belts to thermal paper, carts and PC connectivity items. Keep your monitor running and organized with manufacturer-specified components. Choose the item you need from the options.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFHR ultrasound transducer and TOCO transducer\u003c\/li\u003e\n\u003cli\u003ePatient event marker and transducer belts (pack of 3)\u003c\/li\u003e\n\u003cli\u003eThermal paper, 90 mm x 152 mm x 150 pages, pack of 3\u003c\/li\u003e\n\u003cli\u003eRolling cart with or without tray\u003c\/li\u003e\n\u003cli\u003eRechargeable lithium-ion battery for portable use\u003c\/li\u003e\n\u003cli\u003eRS232-to-USB adapter and Insight connection cable for PC\/EMR connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with the Wallach FETAL2EMR fetal monitor (902300 series).\u003c\/p\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902302 FHR transducer\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003ePulsed Doppler, 1.0 MHz ± 10%; 50–240 bpm; 88 × 35 mm (3.5 × 1.38 in.); 190 g; 2.5 m (8.2 ft) cable; IPX8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902303 TOCO probe\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eExternal uterine activity; 88 × 35 mm; 180 g; 2.5 m cable; IPX8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902304 thermal paper\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eZ-fold thermosensitive, 90 × 152 mm × 150 pages (GE-American type); 3 per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902307 event marker\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eHand-held patient marker; 56 g; 2.5 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902308 belts\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eTransducer belts, 3 per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902322 adapter\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRS232-to-USB adapter with driver; for 902300 and 902300-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902323 cable\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eInsight connection cable for 902300-R; requires Insight software (902320)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902340 \/ 902341 carts\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eRolling cart with laptop tray (902340) or without (902341); fits 902300 and 902300-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e902350 battery\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e14.8 V, 4200 mAh lithium-ion; about 7 h continuous use; 16.8 V charge; 300+ cycles; charge at 0–50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCertification\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCE marked (transducers, TOCO, event marker, belts, cart, battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e90 days (paper: until use or expiration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/www.coopersurgical.com\/wp-content\/uploads\/2026\/10\/CSI_Clinic-Catalog_2026_v4.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Catalog\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Wallach Surgical","offers":[{"title":"FHR Probe \/ Ultrasound Transducer (4-pin)","offer_id":72053901394058,"sku":"902302","price":768.43,"currency_code":"USD","in_stock":true},{"title":"TOCO Probe","offer_id":72053901426826,"sku":"902303","price":624.37,"currency_code":"USD","in_stock":true},{"title":"Thermal Paper 90mm x 152mm x 150p, Pack of 3","offer_id":72053901459594,"sku":"902304","price":39.51,"currency_code":"USD","in_stock":true},{"title":"Event Marker","offer_id":72053901492362,"sku":"902307","price":86.44,"currency_code":"USD","in_stock":true},{"title":"Belts, Pack of 3","offer_id":72053901525130,"sku":"902308","price":69.15,"currency_code":"USD","in_stock":true},{"title":"RS232 to USB Adapter \u0026 Driver","offer_id":72053901557898,"sku":"902322","price":52.7,"currency_code":"USD","in_stock":true},{"title":"Insight Connection Cable","offer_id":72053901590666,"sku":"902323","price":32.93,"currency_code":"USD","in_stock":true},{"title":"Rolling Cart with Tray","offer_id":72053901623434,"sku":"902340","price":1053.65,"currency_code":"USD","in_stock":true},{"title":"Rolling Cart without Tray","offer_id":72053901656202,"sku":"902341","price":1030.68,"currency_code":"USD","in_stock":true},{"title":"Rechargeable Lithium-Ion Battery","offer_id":72053901688970,"sku":"902350","price":548.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Wallach-Surgical-Logo.jpg?v=1794626886"},{"product_id":"summit-doppler-ultrasound-gel-for-dopplers","title":"Summit Doppler Ultrasound Gel for Dopplers","description":"\u003cp\u003eUltrasound coupling gel for handheld and tabletop Doppler exams. Gel removes the air gap between the probe face and the skin so ultrasound energy is transmitted efficiently, which helps you get a clear Doppler signal. Available in two sizes.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eG150: 60 gm\u003c\/li\u003e\n\u003cli\u003eG155: 250 gm\u003c\/li\u003e\n\u003cli\u003eFor use with Summit Doppler LifeDop and other Doppler probes\u003c\/li\u003e\n\u003cli\u003eApply to the probe face only; re-apply if the gel dries or thins out\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eProduct type\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWater-based ultrasound coupling gel for Doppler probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eG150\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e60 gm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eG155\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e250 gm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSummit Doppler LifeDop hand-held and table-top Dopplers and their probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eUse\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eApply to the probe face to remove the air gap between probe and skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/resourcehub.coopersurgical.com\/asset\/f3b266d8-26bd-4782-a6c1-f244c0e6b652\/C-US-CSI-000041-Clinic-Practice-based-Products-Catalog-2026-UPDATE.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Catalog\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Cooper Surgical","offers":[{"title":"250 gm","offer_id":72053901787274,"sku":"G155","price":23.02,"currency_code":"USD","in_stock":true},{"title":"60 gm","offer_id":72053901820042,"sku":"G150","price":15.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Summit-Doppler-Logo.jpg?v=1794626885"},{"product_id":"summit-doppler-lifedop-interchangeable-doppler-probes","title":"Summit Doppler LifeDop® Interchangeable Doppler Probes","description":"\u003cp\u003eInterchangeable Doppler probes for Summit Doppler LifeDop units. Each probe has built-in electronics, so you can swap between obstetric and vascular applications on the same unit and add probes as your needs grow. Select the frequency and type you need.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSD2: 2 MHz OB probe for late-term exams and deeper fetal positions\u003c\/li\u003e\n\u003cli\u003eSD3: 3 MHz OB probe for general and early obstetric use\u003c\/li\u003e\n\u003cli\u003eSDW: 2 MHz waterproof OB probe (IPX7 probe and cable)\u003c\/li\u003e\n\u003cli\u003eSD4: 4 MHz vascular probe with a broad, flat beam for fast vessel location\u003c\/li\u003e\n\u003cli\u003eSD5: 5 MHz vascular probe for deeper vessels\u003c\/li\u003e\n\u003cli\u003eSD8: 8 MHz vascular probe for superficial vessels; STN: 8 MHz sterilizable version for sterile fields\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with LifeDop 150, 250 and 350 Dopplers. Vascular probes (4, 5, 8 MHz) are not for fetal use.\u003c\/p\u003e\n\u003cp style=\"margin-top:10px;margin-bottom:2px\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0\"\u003e\u003ctbody\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eLifeDop L150, L250 and L350 series Dopplers (non-directional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eDoppler mode\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eContinuous wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSD2\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e2 MHz obstetrical, wide beam for late term and larger patients (measured 2.1 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSD3\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e3 MHz obstetrical, wide beam, general purpose from early pregnancy (measured 3.2 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSDW\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e2 MHz obstetrical, waterproof for water-assisted labor (IPX7 probe and cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSD4\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e4 MHz vascular, broad flat beam with tilted crystals for quick vessel location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSD5\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e5 MHz vascular, medium-width pencil probe for deeper vessels (measured 5.3 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSD8\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e8 MHz vascular, narrow-beam pencil probe for surface vessels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSTN\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e8 MHz sterilizable vascular probe, 7 ft straight cable, validated for STERRAD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eCable\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eUser-replaceable modular coil cord on SD2, SD3, SD4, SD5 and SD8 (Gray Coil Cord A155)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#f5f5f5\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWater protection\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eSDW: IPX7; other probes IPX4 within 2.5 cm of tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"IKA -flex-table-row\" style=\"background-color:#ffffff\"\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"IKA -flex-table-column\" style=\"padding:6px 10px;line-height:1.4\"\u003e90 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/LifeDop-Vascular-Sell-Sheet_1eec9bb7-76a3-482a-8608-49896fc868d5.pdf?v=1794789834\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Summit-Doppler-LifeDop-User-Manual_466f3945-1063-4379-83e8-8741d481e3c3.pdf?v=1794789834\" target=\"_blank\" rel=\"noopener\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/resourcehub.coopersurgical.com\/asset\/f3b266d8-26bd-4782-a6c1-f244c0e6b652\/C-US-CSI-000041-Clinic-Practice-based-Products-Catalog-2026-UPDATE.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Catalog\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Cooper Surgical","offers":[{"title":"2 MHz Obstetrical (late-term)","offer_id":72053903294602,"sku":"SD2","price":374.61,"currency_code":"USD","in_stock":true},{"title":"3 MHz Obstetrical (general purpose)","offer_id":72053903327370,"sku":"SD3","price":374.61,"currency_code":"USD","in_stock":true},{"title":"2 MHz Obstetrical Waterproof","offer_id":72053903360138,"sku":"SDW","price":597.14,"currency_code":"USD","in_stock":true},{"title":"4 MHz Vascular (ultra-wide beam)","offer_id":72053903392906,"sku":"SD4","price":374.61,"currency_code":"USD","in_stock":true},{"title":"5 MHz Vascular (deep vessels)","offer_id":72053903425674,"sku":"SD5","price":374.61,"currency_code":"USD","in_stock":true},{"title":"8 MHz Vascular (surface vessels)","offer_id":72053903458442,"sku":"SD8","price":374.61,"currency_code":"USD","in_stock":true},{"title":"8 MHz Sterilizable Vascular","offer_id":72053903491210,"sku":"STN","price":663.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/c88263da-8aca-48a4-9276-85d42d38869fmediumSD4.jpg?v=1794627714"}],"url":"https:\/\/medlabamerica.com\/collections\/fetal-monitor-doppler-accessories.oembed","provider":"MedLabAmerica.com","version":"1.0","type":"link"}