{"title":"Accuris™ SmartDrop™ Nano Spectrophotometers \u0026 Fluorometers","description":"\u003cp\u003eAccuris™ SmartDrop™ micro-volume nano spectrophotometers for DNA, RNA and protein quantification, including the SmartDrop™ L, full-spectrum SmartDrop™ X and SmartDrop™ XF with fluorometer, plus cuvettes, printer paper and pedestal reconditioning solution.\u003c\/p\u003e","products":[{"product_id":"accuris-smartdrop-l-nano-spectrophotometer-ns1000","title":"Accuris™ SmartDrop™ L Nano Spectrophotometer, 260\/280 nm, Touch Screen, NS1000","description":"\u003cp\u003eThe Accuris™ SmartDrop™ series of nano spectrophotometers provides quick and easy quantification of small samples. Using a microvolume sample eliminates the need for dilutions, providing more accurate results. A full-color 7-inch touch screen with icon-driven menus and preprogrammed protocols gets users up and running quickly, and no external computer or software is required.\u003c\/p\u003e\n\u003cp\u003eThe SmartDrop™ L (NS1000) is the affordable choice for laboratories that need to determine nucleic acid and protein concentrations and sample purity. Its LED light source and silicon photocell sensor provide readings at 260 and 280 nm. Samples from 1.0 to 2.0 µl are loaded directly on the pedestal, results are provided in about 5 seconds, and the software automatically calculates and displays 260\/280 ratios.\u003c\/p\u003e\n\u003cp\u003eEach unit features a quartz pedestal onto which a drop of sample is placed. The arm is lowered and the drop is stretched into a liquid column of specified length for spectral analysis; DNA, RNA and protein concentrations and purity ratios are displayed in a matter of seconds. Results can be printed on the integrated printer, saved in onboard memory or exported by USB as an Excel file. For OD600 readings of bacterial cultures, every model includes a cuvette port and two optical glass cuvettes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for basic DNA\/RNA\/protein quantification and purity\u003c\/li\u003e\n\u003cli\u003eAffordable UV LED and silicon detector technology\u003c\/li\u003e\n\u003cli\u003eFixed 0.5 mm path length; detects up to 2,500 ng\/µl dsDNA\u003c\/li\u003e\n\u003cli\u003e7-inch color touch screen; no PC or software required\u003c\/li\u003e\n\u003cli\u003eMicrovolume quartz pedestal — no dilutions\u003c\/li\u003e\n\u003cli\u003eIntegrated printer; onboard memory; USB export to Excel\u003c\/li\u003e\n\u003cli\u003eCuvette port for OD600 readings, 2 optical glass cuvettes included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAccessories: \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smartdrop-accessories-ns1000\"\u003eSmartDrop™ cuvettes, printer paper and pedestal reconditioning solution\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAccuris™ SmartDrop™ L, NS1000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e7-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e1.0–2.0 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePath Length\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUV LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUV silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e260, 280 \u0026amp; 600 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.2–50 A (10 mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Precision\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.005 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLower Limit of Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 10 ng\/µl; BSA 0.5 mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUpper Limit of Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 2,500 ng\/µl; BSA 75.0 mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetection Time\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCuvette OD600 Absorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.0–4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUSB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eVoltage Input \/ Power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDC 24V, 2A \/ 25W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e8.2 x 11.0 x 7.3 in (20.8 x 28.0 x 18.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e3.6 kg (7.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop Series Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/10\/NS1000-Operation-Manual-V1.2.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop L NS1000 Operation Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"US Plug - 115V","offer_id":72016100556938,"sku":"NS1000","price":6132.02,"currency_code":"USD","in_stock":true},{"title":"EU Plug - 230V","offer_id":72016100589706,"sku":"NS1000-E","price":6132.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/NS1000-SmartDrop-L-Front.jpg?v=1794449085"},{"product_id":"accuris-smartdrop-x-nano-spectrophotometer-ns1010","title":"Accuris™ SmartDrop™ X Full-Spectrum Nano Spectrophotometer, 200-800 nm, NS1010","description":"\u003cp\u003eThe Accuris™ SmartDrop™ series of nano spectrophotometers provides quick and easy quantification of small samples. Using a microvolume sample eliminates the need for dilutions, providing more accurate results. A full-color 7-inch touch screen with icon-driven menus and preprogrammed protocols gets users up and running quickly, and no external computer or software is required.\u003c\/p\u003e\n\u003cp\u003eThe SmartDrop™ X (NS1010) is a full-spectrum UV-Vis nano spectrophotometer requiring only 0.5 to 2.0 µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full-spectrum scan from 200 to 800 nm takes about 6 seconds, aiding the identification of unknowns, and up to 5 specific wavelengths can be selected for colorimetric output. The long-life xenon flash lamp needs no warm-up and is paired with a highly sensitive 2048-element CCD detector, and auto-ranging 0.2 mm and 1.0 mm path lengths deliver accurate results across a wide concentration range.\u003c\/p\u003e\n\u003cp\u003eEach unit features a quartz pedestal onto which a drop of sample is placed. The arm is lowered and the drop is stretched into a liquid column of specified length for spectral analysis; DNA, RNA and protein concentrations and purity ratios are displayed in a matter of seconds. Results can be printed on the integrated printer, saved in onboard memory or exported by USB as an Excel file. For OD600 readings of bacterial cultures, every model includes a cuvette port and two optical glass cuvettes.\u003c\/p\u003e\n\u003cp\u003eThe SmartDrop™ X includes a Performance Verification software feature for use with the NS1010-PVF-1 performance verification fluid (available separately; feature incorporated in instruments manufactured in 2024 and later).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull-spectrum absorbance scans, 200–800 nm\u003c\/li\u003e\n\u003cli\u003eCalculates and displays 260\/280 and 260\/230 ratios\u003c\/li\u003e\n\u003cli\u003eLong-life xenon lamp with precision monochromator\u003c\/li\u003e\n\u003cli\u003eAuto-ranging path lengths of 0.2 mm and 1.0 mm\u003c\/li\u003e\n\u003cli\u003eDetects up to 4,500 ng\/µl dsDNA without dilution\u003c\/li\u003e\n\u003cli\u003ePreset BCA, Bradford and Lowry protein assays\u003c\/li\u003e\n\u003cli\u003e7-inch color touch screen; no PC or software required\u003c\/li\u003e\n\u003cli\u003eMicrovolume quartz pedestal — no dilutions\u003c\/li\u003e\n\u003cli\u003eIntegrated printer; onboard memory; USB export to Excel\u003c\/li\u003e\n\u003cli\u003eCuvette port for OD600 readings, 2 optical glass cuvettes included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAccessories: \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smartdrop-accessories-ns1000\"\u003eSmartDrop™ cuvettes, printer paper and pedestal reconditioning solution\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAccuris™ SmartDrop™ X, NS1010\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e7-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.5–2.0 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePath Length\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.2 mm, 1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eXenon flash lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2048-element linear silicon CCD array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e200–800 nm (1 nm steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.04–90 A (10 mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Precision\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.003 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLower Limit of Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 2 ng\/µl; BSA 0.1 mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUpper Limit of Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 4,500 ng\/µl; BSA 135 mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetection Time\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u0026lt; 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCuvette OD600 Absorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.0–4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUSB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eVoltage Input \/ Power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDC 24V, 2A \/ 25W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e8.2 x 11.0 x 7.3 in (20.8 x 28.0 x 18.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e3.6 kg (7.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop Series Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/10\/NS1010-Operation-Manual-V1.4.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop X NS1010 Operation Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2026\/10\/NS1010-PVF_Accuris-V1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris NS1010-PVF Performance Verification Solution\"\u003ePerformance Verification\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"US Plug - 115V","offer_id":72016100786314,"sku":"NS1010","price":11341.28,"currency_code":"USD","in_stock":true},{"title":"EU Plug - 230V","offer_id":72016100819082,"sku":"NS1010-E","price":11341.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/NS1010-SmartDrop-X-Front.jpg?v=1794449086"},{"product_id":"accuris-smartdrop-xf-nano-spectrophotometer-fluorometer-ns1020","title":"Accuris™ SmartDrop™ XF Nano Spectrophotometer with Fluorometer, 200-800 nm, NS1020","description":"\u003cp\u003eThe Accuris™ SmartDrop™ series of nano spectrophotometers provides quick and easy quantification of small samples. Using a microvolume sample eliminates the need for dilutions, providing more accurate results. A full-color 7-inch touch screen with icon-driven menus and preprogrammed protocols gets users up and running quickly, and no external computer or software is required.\u003c\/p\u003e\n\u003cp\u003eThe SmartDrop™ XF (NS1020) is the top-of-the-line model, performing UV-Vis readings from 200 to 800 nm as well as fluorescence readings. Like the SmartDrop™ X, it features predefined programs for nucleic acids, proteins and colorimetric assays. Its patented motorized system gently stretches the sample column and provides three path lengths (0.05, 0.2 and 1.0 mm), giving accurate readings of 0.5 to 2.0 µl samples up to 15,000 ng\/µl dsDNA without dilution.\u003c\/p\u003e\n\u003cp\u003eThe integrated fluorometer yields more accurate, sensitive and selective quantitation of low-concentration nucleic acids. The blue channel (460 nm excitation) is suited to dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein, with dsDNA sensitivity down to 0.5 pg\/µl. It is designed for use with Accuris DNA and RNA quantification kits and 0.5 ml fluorescence detection tubes.\u003c\/p\u003e\n\u003cp\u003eEach unit features a quartz pedestal onto which a drop of sample is placed. The arm is lowered and the drop is stretched into a liquid column of specified length for spectral analysis; DNA, RNA and protein concentrations and purity ratios are displayed in a matter of seconds. Results can be printed on the integrated printer, saved in onboard memory or exported by USB as an Excel file. For OD600 readings of bacterial cultures, every model includes a cuvette port and two optical glass cuvettes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUV-Vis spectrophotometer plus integrated fluorometer\u003c\/li\u003e\n\u003cli\u003eFull-spectrum absorbance scans, 200–800 nm; 260\/280 and 260\/230 ratios\u003c\/li\u003e\n\u003cli\u003eLong-life xenon lamp with precision monochromator\u003c\/li\u003e\n\u003cli\u003eAuto-ranging path lengths of 0.05, 0.2 and 1.0 mm\u003c\/li\u003e\n\u003cli\u003eDetects up to 15,000 ng\/µl dsDNA without dilution\u003c\/li\u003e\n\u003cli\u003eFluorescence sensitivity to 0.5 pg\/µl dsDNA\u003c\/li\u003e\n\u003cli\u003e7-inch color touch screen; no PC or software required\u003c\/li\u003e\n\u003cli\u003eMicrovolume quartz pedestal — no dilutions\u003c\/li\u003e\n\u003cli\u003eIntegrated printer; onboard memory; USB export to Excel\u003c\/li\u003e\n\u003cli\u003eCuvette port for OD600 readings, 2 optical glass cuvettes included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAccessories: \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smartdrop-accessories-ns1000\"\u003eSmartDrop™ cuvettes, printer paper and pedestal reconditioning solution\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFluorescence consumables: \u003ca href=\"https:\/\/medlabamerica.com\/search?q=F1001-T\"\u003e0.5 ml fluorescence detection tubes\u003c\/a\u003e and \u003ca href=\"https:\/\/medlabamerica.com\/search?q=Accuris+quantification+kit\"\u003eAccuris DNA\/RNA quantification kits\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAccuris™ SmartDrop™ XF, NS1020\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e7-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.5–2.0 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePath Length\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.05 mm, 0.2 mm, 1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eXenon flash lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2048-element linear silicon CCD array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e200–800 nm (1 nm steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.04–300 A (10 mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eAbsorbance Precision\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.003 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eLower Limit of Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 2 ng\/µl; BSA 0.1 mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUpper Limit of Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 15,000 ng\/µl; BSA 450 mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDetection Time\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCuvette OD600 Absorbance Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e0.0–4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eFluorescence Excitation \/ Emission\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e460 ± 20 nm \/ 525–570 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eFluorescence Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003edsDNA 0.5 pg\/µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eFluorescence Linearity\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eR² ≥ 0.995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eFluorescence Repeatability \/ Stability\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e≤ 1.5% \/ ≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eUSB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eVoltage Input \/ Power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDC 24V, 2A \/ 25W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e8.2 x 12.6 x 7.3 in (20.8 x 32.0 x 18.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e3.6 kg (7.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop Series Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/10\/NS1020-Operation-Manual-V1.2.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop XF NS1020 Operation Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"US Plug - 115V","offer_id":72016104161418,"sku":"NS1020","price":13405.21,"currency_code":"USD","in_stock":true},{"title":"EU Plug - 230V","offer_id":72016104194186,"sku":"NS1020-E","price":13405.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/NS1020-SmartDrop-XF-Front.jpg?v=1794449087"},{"product_id":"accuris-smartdrop-accessories-ns1000","title":"Accuris™ SmartDrop™ Cuvettes, Printer Paper \u0026 Pedestal Reconditioning Solution, NS1000 Accessories","description":"\u003cp\u003eGenuine Accuris™ accessories and consumables for the SmartDrop™ L, X and XF nano spectrophotometers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Items:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-bottom:0\"\u003e\n\u003cli\u003eNS1000-C: Additional standard-size optical glass cuvettes for the OD600 cuvette port, pack of 2\u003c\/li\u003e\n\u003cli\u003eNS1000-PA: Extra paper rolls for the SmartDrop™ internal printer, pack of 3\u003c\/li\u003e\n\u003cli\u003eNS1000-RS: SmartDrop™ pedestal reconditioning solution, 1.0 ml\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible instruments: \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smartdrop-l-nano-spectrophotometer-ns1000\"\u003eSmartDrop™ L, NS1000\u003c\/a\u003e, \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smartdrop-x-nano-spectrophotometer-ns1010\"\u003eSmartDrop™ X, NS1010\u003c\/a\u003e and \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-smartdrop-xf-nano-spectrophotometer-fluorometer-ns1020\"\u003eSmartDrop™ XF, NS1020\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris SmartDrop Series Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"Cuvettes, pack of 2 NS1000-C","offer_id":72016104620170,"sku":"NS1000-C","price":55.44,"currency_code":"USD","in_stock":true},{"title":"Printer Paper, pack of 3 NS1000-PA","offer_id":72016104652938,"sku":"NS1000-PA","price":40.9,"currency_code":"USD","in_stock":true},{"title":"Pedestal Reconditioning Solution, 1.0 ml NS1000-RS","offer_id":72016104685706,"sku":"NS1000-RS","price":95.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/NS1000-C-Cuvettes.jpg?v=1794449087"}],"url":"https:\/\/medlabamerica.com\/collections\/accuris-smartdrop-nano-spectrophotometers.oembed","provider":"MedLabAmerica.com","version":"1.0","type":"link"}