{"title":"Accuris™ QuadCount™ Automated Cell Counters \u0026 QuadSlides™","description":"\u003cp\u003eThe Accuris™ QuadCount™ automated cell counter for fast, accurate cell counts and viability, with QuadSlides™, standard test slides and a barcode scanner.\u003c\/p\u003e","products":[{"product_id":"accuris-quadcount-automated-cell-counter-e7500","title":"Accuris™ QuadCount™ Automated Cell Counter, E7500","description":"\u003cp\u003eThe Accuris™ E7500 QuadCount™ Automated Cell Counter improves on simple brightfield microscopy with an LED light source, precision optics and a high-resolution CMOS detector. A finely tuned, motorized XYZ stage provides extra-fine focusing and captures multiple images, delivering fast, accurate and reproducible cell counts with as little as 20 seconds per sample.\u003c\/p\u003e\n\u003cp\u003eCompared with tedious manual hemocytometry, QuadCount™ software eliminates human bias in live\/dead determination, reduces counting errors and saves time. Advanced detection algorithms correctly analyze irregularly shaped and aggregated cells that are often misinterpreted visually, removing user-to-user variation. A proprietary autofocus system works with the motorized stage to capture images in the proper focal plane — essential for accurate viable-cell counts.\u003c\/p\u003e\n\u003cp\u003eThe QuadCount™ uses unique 4-chamber disposable QuadSlides™, processing four samples per slide — twice the capacity of standard 2-chamber slides — to lower consumable costs. Three count modes analyze different sample volumes: Quick (0.15 µl, 1 frame, 20 s), Normal (0.9 µl, 6 frames, 30 s) and Precise (3.6 µl, 24 frames, 100 s). Analyzing larger volumes across multiple frames provides significantly better accuracy.\u003c\/p\u003e\n\u003cp\u003eAfter capture, gating size range, aggregation level and live\/dead definition are easily adjusted on the touch screen, and population statistics are displayed as a histogram for individual or multiple chambers. USB ports connect a printer, external keyboard or flash drive, and detailed PDF reports can be exported for saving or printing. The QuadCount™ is compatible with most common mammalian cell lines, including HeLa, Jurkat T and HCT116.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast, accurate and reproducible counts — as fast as 20 seconds per sample\u003c\/li\u003e\n\u003cli\u003eIntuitive software and touch-screen interface\u003c\/li\u003e\n\u003cli\u003eConvenient, cost-effective 4-chamber QuadSlides™\u003c\/li\u003e\n\u003cli\u003eCounts sample volumes up to 3.6 µl (24 image frames)\u003c\/li\u003e\n\u003cli\u003eAutofocus with motorized XYZ stage\u003c\/li\u003e\n\u003cli\u003eAdvanced algorithms for irregular and aggregated cells\u003c\/li\u003e\n\u003cli\u003eAdjustable gating, aggregation and live\/dead parameters\u003c\/li\u003e\n\u003cli\u003ePDF reports exported by USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" id=\"tech_data\" style=\"margin-top:0;margin-bottom:0;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e\u003cstrong\u003eAccuris™ QuadCount™ E7500\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eOptics\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eHigh-quality 4x objective lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eImage Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e5-megapixel CMOS sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePixel Resolution\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e2592 x 1944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eIllumination\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eGreen LED (50,000-hour life)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e20 µl (4 samples per QuadSlide™)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eMax. Counting Volume\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e3.6 µl (24 image captures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eConsumable Slide\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eQuadSlide™, 4-chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCounting Modes \/ Speeds\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eQuick (20 s), Normal (30 s), Precise (100 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDynamic Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e1 x 10\u003csup\u003e4\u003c\/sup\u003e to 1 x 10\u003csup\u003e7\u003c\/sup\u003e cells\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eCell Size Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e5 to 60 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eData Output\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003ePDF report to USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e16.3 x 29.3 x 21.6 cm (6.4 x 11.5 x 8.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e11 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f5f5f5\"\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;line-height:1.4\"\u003e115V (E7500) or 230V (E7500-E), 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2021\/03\/E7500-Accuris-QuadCount.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris QuadCount Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/06\/E7500-QuadCount-User-Manual-1.2-3-3-2020.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris QuadCount E7500 User Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/09\/QuadCount-Cell-line-compatibility-test_8-2-2021.pdf\" target=\"_blank\" rel=\"noopener\" title=\"QuadCount Cell Line Compatibility Report\"\u003eCell Line Compatibility\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"US Plug - 115V","offer_id":72015945367690,"sku":"E7500","price":4224.91,"currency_code":"USD","in_stock":true},{"title":"EU Plug - 230V","offer_id":72015945400458,"sku":"E7500-E","price":4224.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Accuris-E7500-QuadCount-Automated-Cell-Counter.jpg?v=1794447344"},{"product_id":"accuris-quadcount-accessories-e7500","title":"Accuris™ QuadCount™ QuadSlides™, Standard Test Slide \u0026 Barcode Scanner, E7500 Accessories","description":"\u003cp\u003eGenuine consumables and accessories for the Accuris™ QuadCount™ Automated Cell Counter (E7500).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuadSlides™ (E7500-S1, pack of 50):\u003c\/strong\u003e unique 4-chamber disposable counting slides that process four samples per slide — twice the capacity of standard 2-chamber slides — to lower consumable costs. Each chamber has a hydrophilic inner surface with an engraved grid pattern, and high-precision production and molding ensure every QuadSlide™ meets the rigorous standards and dimensional tolerances required for optimal counting performance. Sample volume is 20 µl per chamber.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Test Slide (E7500-STS1, pack of 1):\u003c\/strong\u003e a reference slide for checking QuadCount™ performance as part of routine verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBarcode Scanner (E7500-BS, pack of 1):\u003c\/strong\u003e an optional scanner for the QuadCount™.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-bottom:0\"\u003e\n\u003cli\u003e4-chamber QuadSlides™ — four samples per slide\u003c\/li\u003e\n\u003cli\u003eHydrophilic chambers with engraved grid pattern\u003c\/li\u003e\n\u003cli\u003eHigh-precision molding for consistent counting performance\u003c\/li\u003e\n\u003cli\u003eFor the Accuris™ QuadCount™ E7500 \/ E7500-E\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible counter: \u003ca href=\"https:\/\/medlabamerica.com\/products\/accuris-quadcount-automated-cell-counter-e7500\"\u003eAccuris™ QuadCount™ Automated Cell Counter, E7500\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdiv data-mla-docs=\"1\" style=\"border:1px solid #13275C;border-radius:6px;overflow:hidden;margin:14px 0 0\"\u003e\n\u003cp style=\"margin:0;padding:6px 14px;background:#13275C;color:#ffffff;font-weight:700;font-size:12px;letter-spacing:.08em;text-transform:uppercase\"\u003eProduct Documents\u003c\/p\u003e\n\u003cp style=\"margin:0;padding:12px 14px\"\u003e\u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2021\/03\/E7500-Accuris-QuadCount.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris QuadCount Brochure\"\u003eBrochure\u003c\/a\u003e\u003c\/span\u003e  |  \u003cspan style=\"white-space:nowrap\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Adobe_Icon_368009cd-f452-4bd7-b577-5709c393fd67.png?v=1782487710\" alt=\"PDF\" width=\"16\" height=\"16\" style=\"width:16px;height:16px;object-fit:contain;vertical-align:middle;margin-right:6px\"\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/06\/E7500-QuadCount-User-Manual-1.2-3-3-2020.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Accuris QuadCount E7500 User Manual\"\u003eProduct Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Accuris Scientific","offers":[{"title":"QuadSlides, Pack of 50 E7500-S1","offer_id":72015964471434,"sku":"E7500-S1","price":156.96,"currency_code":"USD","in_stock":true},{"title":"Standard Test Slide E7500-STS1","offer_id":72015964504202,"sku":"E7500-STS1","price":263.39,"currency_code":"USD","in_stock":true},{"title":"Barcode Scanner E7500-BS","offer_id":72015964536970,"sku":"E7500-BS","price":269.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/2669\/8378\/files\/Accuris-E7500-S1-QuadSlide.jpg?v=1794447343"}],"url":"https:\/\/medlabamerica.com\/collections\/accuris-quadcount-cell-counters.oembed","provider":"MedLabAmerica.com","version":"1.0","type":"link"}